Pressure Control Module PCM-20
Designed to control Double pumps of Hi-Low system. Unloads low pressure pump when system pressure rises above the pressure set on Unloader valve.
Product Description
Relieves high pressure pump when system pressure reaches the value. Solenoid unloading facility available as an option
Technical  specifications: 
Construction PCM 20/06 and 20/10 …..Direct acting poppet type high pr. relief valve.Two stage poppet type low pressure unloading valve.
Mounting    ……………………………………Threaded body ( Factory  standard )
Mounting  position    …………………………Optional
Flow  direction    ……………………………..As per hydraulic symbol.
Operating  pressure    ………………………For low pressure pump 50 and 100 bar.For high pressure pump port 100, 200, 315.
Hydraulic  medium    ………………………..Mineral oil.
Viscosity  range    ……………………………10  cSt  to  380  cSt.
Fluid temperature range  …………………-20°C  to  +70°C.Fluid cleanliness requirement  ………….ISO 4406  20/18/15 or better
Mass    …………………………………………..  7.5  kg.    APPROX.
	
					
 
              