Pilot Operated Check Valve CI06
Pilot operated Check valves model CI06 allow free flow in the direction from Port A to Port B and offer leakage free closure in opposite direction.
Product Description
Reverse flow can be achieved by applying pilot pressure to their Port X. The intensity of pilot pressure required to keep the valve open during reverse flow depends upon the valve model, pressure at Port A and pressure existing at the Port B when the reverse flow starts. Pilot pressure can be calculated using formulae given below.
In most cases, smooth decompression and opening of the valve  for  flow  from Port B to Port A can be effectively  achieved  by controlling pressure  and  flow to  the Pilot Port X. However,  in  certain  cases  it  is  necessary  to  decompress  the  oil in the cylinder first before admitting the oil in the cylinder for the return stroke for smooth reversal.
	
					
 
              